Checking The Thermostat And Heater Contactor


You need to find the Heater Contactor in the control box (see picture).


If the heater contactor it is not arced/welded shut and moves up and down freely, then the thermostat needs to be replaced. Thermostats are located in one of two places on a spa, either on the top of the spa (spa sides), or in a control box where the equipment is.


See Thermostats in Spa Parts section. Replace the contactor if it was arced/welded shut. 

See contactors in Spa Parts section. 

In some cases, both of these will need to be replaced.

NOTE: Contactors arc or weld themselves shut due to "chattering" caused by: 

  • Low water level in spa 
  • Pressure switch out of adjustment 
  • Clogged or old filter 
  • Solid state thermostats 

ONE MORE NOTE: Leaving your jets (jet pump) on for a long period of time will also cause the water to over heat.